HURRICANE OFF ROAD

HURRICANE OFF ROAD LAKE CHARLES, LA 5,100 SF | CUSTOMIZED PRE-ENGINEERED METAL BUILDING | COMPLEX EXTERIOR METAL WORK | SPECIALIZED CARPENTRY AND FINISHING | SPECIALIZED EPOXY FLOOR COATING | STATE OF THE ART LIGHTING SYSTEM

Read More

SPRINGHILL SUITES BY MARRIOT

SPRINGHILL SUITES BY MARRIOT LAKE CHARLES, LA 72000 SQ FT | 5 STORY BUILDING | 108 GUEST ROOMS | FF&E INSTALLATION | GUEST LOUNGES | SWIMMING POOL | INDOOR SWIMMING POOL | LANDSCAPE IMPROVEMENTS | 7,500 SF CONFERENCE CENTER

Read More

CITY OF LAKE CHARLES-BUS TRANSIT STATION

CITY OF LAKE CHARLES-BUS TRANSIT STATION LAKE CHARLES, LA 12800 SF | DEMOLITION AND RENOVATION OF 14” CAST IN PLACE CONCRETE STRUCTURE | INTERIOR AND EXTERIOR RENOVATION | INSTALLATION OF SITE UTILITIES | ARCHITECTURAL BUS TRANSFER CANOPY | METAL STUD FRAMING AND BRICK VENEER | AUTOMATED ELECTRICAL AND MECHANICAL SYSTEM | CUSTOM WATER FEATURE |…

Read More

UNITED STATES AIR FORCE-TRANSFORMERS AWUB 13-0132

UNITED STATES AIR FORCE-TRANSFORMERS AWUB 13-0132 BARKSDALE AFB AIR FORCE BASE, LA | PROVIDE ALL LABOR, MATERIALS, EQUIPMENT & SUPERVISION | DISCONNECT & REMOVE EXISTING TRANSFORMER 2000 KVA, 12,470 VOLT/480Y/277 DELTA WYE OIL FILLED | INSPECT AND REPAIR CONCRETE PAD & FOUNDATION | CUSTOMIZE AND FABRICATE NEW TRANSFORMERS | INSTALL NEW TRANSFORMER 2000 KVA, 12,470…

Read More

USACE SEEPAGE REPAIR

USACE SEEPAGE REPAIR NEW ORLEANS, LA 21,648 LINEAR FEET | CRACKS REPAIR BY INJECTING HYDROPHILIC URETHANE | SPALL REMOVAL AND REPAIR | SATURATED SURFACE DRY CONDITION | DAYTON SUPERIOR HD-50 REPAIR MORTAR

Read More

USACE STORM PROOFING-WESTMINSTER LINCOLNSHIRE PUMP STATION

USACE STORM PROOFING-WESTMINSTER LINCOLNSHIRE PUMP STATION MARRERO, LA UPGRADED STRUCTURES TO WITHSTAND WIND RESISTANCE OF 160 MPH | 11’X11’ RAISED STRUCTURAL CONCRETE PLATFORM | INSTALLATION OF AUTOMATED BACKUP GENERATOR | FABRICATION AND INSTALLATION OF 20 TON DEFLECTOR PLATES INSTALLATION OF ANTI-MISSILE DAMPERS | ERECTION OF 50 TON WALLS | INSTALLATION OF WIND RATED STANDING SEAM…

Read More

USACE JSP-08A, STORM PROOFING INTERIOR PUMP STATION

USACE JSP-08A, STORM PROOFING INTERIOR PUMP STATION JEFFERSON PARISH, LA | STRUCTURAL, MECHANICAL AND ELECTRICAL UPGRADES | INSTALLATION OF VENTILATION FANS | AUTOMATION OF EXISTING DAMPERS | INSTALLATION OF NEW AUTOMATIC LUBRICATORS | INSTALLATION OF NEW ELECTRIC ACTUATORS FOR VALVES | REINFORCEMENT OF TRASH RAKE MOTORS

Read More

USACE ATCHAFALAYA BASIN LEVEE ENLARGEMENT

USACE ATCHAFALAYA BASIN LEVEE ENLARGEMENT ST. MARY PARISH, LA CLEARING & GRUBBING | SOIL TESTING | LIME SOIL AMENDMENT & SULPHUR SOIL AMENDMENT | INSTALLATION OF GEO-TEXTILE SEPARATOR | INSTALLATION OF 610 SURFACING | BORROW PIT DEVELOPMENT | EMBANKMENT | COMPACTED FILL & SURFACING | HYDROSEEDING & HYDROMULCHING | CONCRETE SCOUR PROTECTION

Read More